Workshop content
Day 1: Theoretically oriented workshop content
Background information about magnet drive centrifugal pumps
- Application domain of magnet drive centrifugal pumps and how they work
- Design/configuration variants
Flow technology
- General flow calculations; relevant factors, parameters and variables
Dismantling and mounting
- Consequences of improper maintenance
- Causes of problems; damage analysis methods
Commissioning
- Monitoring methods
- Preventive maintenance
Causes and elimination of malfunctions
- Diagnosis
- Analysis based on damage incurred
- Ensuring installation availability
Day 2: Practice-oriented workshop content
Practical training / magnet drive centrifugal pump
- Mounting and dismantling
- Mounting errors and their consequences
- Manufacture of magnet drive centrifugal pumps
- Damage analysis
Test stand processes
- Centrifugal pump commissioning
- Use of characteristic curves
- Simulations of the causes of malfunction such as running a pump dry or commissioning it incorrectly
- Monitoring methods and their purpose
Concluding discussion
- ...
- ..
- .